FEATURE
|
AK200A
|
AK200FMV
|
AK100
|
AK155
|
| Multi-Pool
Control, the ability of the controller to controll seperate independant
bodies of water. |
1
Pool
|
3
Pools
|
1
Pool
|
1
Pool
|
| Adjustable
Setpoints allows for modifying the setpoint using programming. |
YES
|
YES
|
YES
|
YES
|
| Password
Protection |
4
LEVELS
|
4
LEVELS
|
NO
|
Remote
Yes
|
| Adjustable
Alarm Setpoints, allows for modifying the alarms as desired. |
YES
|
YES
|
Automatic
|
Automatic
|
| External
Alarm Siren or Light |
Supported
|
Supported
|
No
|
No
|
| Seperate
Overfeed Protection for Each Relay |
YES
|
YES
|
YES
|
YES
|
| INPUTS:
pH/Orp/ppm Inputs |
1/1/0
|
3/3/3
|
1/1/0
|
1/0/1
|
| INPUTS:
Temperature/Conductivity |
1/0
|
3/3*
|
0/0
|
0/0
|
| Calculated
PPM |
Yes
|
Yes
|
No
|
No
|
| Digital
Display |
408
Characters
|
408
Characters
|
6
Digits
|
6
Digits
|
| Modem/
RS232 Comm Port for PC |
Option/YES
|
YES/
YES
|
NO
|
YES/NO
|
| DATA
RECORDING |
51,000
samples
|
500,000
samples
|
NO
|
82
samples
|
| 110
and/or 220 VAC Operation |
YES
|
YES
|
YES
|
YES
|
| Remote
Re-Programmable |
Optional
|
YES
|
NO
|
YES
|
| Relays
selectable output voltage |
VAC
in/24VAC
|
VAC
in/24VAC
|
VAC
in/24VAC
|
VAC
in/24VAC
|
| OUTPUT
RELAYS |
4
- 64
|
4
- 64
|
2
|
2
|
| SWITCH
INPUTS |
3
|
9
|
1
|
1
|
| Multi-Language
Support |
YES
|
YES
|
NA
|
NA
|
| Software
Updates |
FREE
|
FREE
|
$35
|
$35
|
| Calibration |
1
to 3 point
|
1
to 3 point
|
1
point
|
2
point
|
| PC
Software Supplied |
YES
|
YES
|
YES
|
YES
|
| Super-Chlorination |
YES
|
YES
|
YES
|
YES
|
| Pager
Notification on Alarms |
YES-4
|
YES-4
|
NO
|
YES-2
|
| Pager
Codes for Alarm Type |
YES
|
YES
|
NO
|
YES
|
| BACKWASH
AUTOMATION |
YES
|
YES
|
NO
|
NO
|
| Multiple
Stage Filter Backwasy |
YES
|
YES
|
NO
|
NO
|
| HEATER
AUTOMATION |
YES
|
YES
|
NO
|
NO
|
| Record
Service Access Times |
YES
|
YES
|
NO
|
NO
|
| Field
Upgradable |
YES
|
YES
|
OPTIONAL
|
NO
|
| Langelier
Saturation Index |
YES
|
YES
|
NO
|
NO
|
| Digital
Flow Meters |
1
|
3
|
NO
|
NO
|
| Included
Flow Cells |
1
|
3
|
1
|
1
|
| Back
Lit Display |
YES
|
YES
|
NA
|
NA
|
| Voice |
Optional
|
YES
|
NO
|
NO
|
| MODEM |
Optional
|
14.4K
Baud
|
NO
|
2400
Baud
|
| Press
for Specs |
AK200
|
AK100 |
AK105 |